Quantitative Computed Tomography by Means of Spectral Detection Spectral detection of X-rays might provide a significant contribution to the creation of several new medical applications in the field of computed tomography. For this
purpose the interaction between the measurement quality of the detector and the resulting image quality is very complex. The complete CT-imaging chain starting with data acquisition with the detector and reconstruction to image quality assessment should be investigated in the scope of this project. A part of the investigation is to find out, if quantitatively exact CT is feasible by means of an accurate description and correction of the CT measurement. Therefore the imaging chain should be
utilized for inspection and optimization of the properties of spectral measurements. | Project manager: Prof. Dr.-Ing. Joachim Hornegger, Heismann, Björn
Project participants: Dr.-Ing. Michael Balda, M. Sc., Niederlöhner, Daniel
Keywords: CT; quantitative computed tomography; spectral detection; dual-energy reconstruction; objective image quality assessment
Duration: 1.1.2007 - 31.12.2009
Sponsored by: Siemens Medical Solutions
Contact: Balda, Michael Phone +49 9131 9189774, Fax +49 9131 9189772, E-Mail: michael.balda@informatik.uni-erlangen.de
| Publications |
---|
Balda, Michael ; Niederlöhner, Daniel ; Kreisler, Björn ; Durst, Jürgen ; Heismann, Björn: Look-up Table-Based Simulation of Directly-Converting Counting X-Ray Detectors for Computed Tomography. In: Yu, Bo (Ed.) : 2009 IEEE Nuclear Science Symposium Conference Record (IEEE Medical Imaging Conference 2009 Orlando, USA 25 - 31 Oktober 2009). Vol. N/A, N/A. Edition N/A : Omnipress, 2009, pp 2588-2593. | Balda, Michael ; Wirth, Stefan ; Daniel Niederlöhner ; Heismann, Björn ; Hornegger, Joachim: Look-up Table-Based Simulation of Scintillation Detectors in Computed Tomography. In: Sellin, Paul (Ed.) : 2008 IEEE Nuclear Science Symposium Conference Record (IEEE Medical Imaging Conference 2008 Dresden 19 - 25 October 2008). 2008, pp 4028-4033. - ISBN 978-1-4244-2715-4 | Heismann, Björn ; Balda, Michael: Quantitative image-based spectral reconstruction for computed tomography. In: Medical Physics 36 (2009), No. 10, pp 4471-4485 [doi>10.1118/1.3213534] | Balda, Michael ; Heismann, Björn ; Hornegger, Joachim: Non-stationary CT image noise spectrum analysis. In: Meinzer, Hans-Peter ; Deserno, Thomas Martin ; Handels, Heinz ; Tolxdorff, Thomas (Ed.) : Bildverarbeitung für die Medizin (BVM 2010 Aachen 14.3.-16.3.). Berlin : Springer, 2010, pp 191-195. | Balda, Michael: Quantitative CT with Local Spectral Reconstruction.Talk: Workshop on Advanced Imaging and Pattern Recognition, Pattern Recognition Lab, FAU and Chair for Computer Aided Medical Procedures, TUM, Regensburg, 26.11.2009 | Balda, Michael: CT Projektionsfilterung unter Berücksichtigung von Messkorrelationen.Talk: Kolloquium Detektorzentrum, Siemens AG, Healthcare Sector, Forchheim, 21.8..2009 | Balda, Michael: SimID - Simulation package for UFC based CT detectors.Talk: Physik Kolloquium CT, Siemens AG, Healthcare Sector, Forchheim, 07.04..2008 |